The MAC 10® LEDC 4 x 4 is a versatile fan filter unit that is designed for the most challenging cleanroom applications. It offers significant cost savings and electrical efficiencies for large cleanrooms.

The MAC 10® LEDC 4 x 4 maximizes energy efficiencies with its exclusive backward blower wheel design. It provides 90 fpm airflow up to 1.0" wg static pressure levels enabling cleanroom projects to operate cost effectively.
Envirco® MAC 10® LEDC 4 x 4 Fan Filter Units
Envirco® MAC 10® LEDC 1950 Cubic Feet per Minute (ft³/min) Maximum Air Flowrate 4 x 4 Fan Filter Unit - 2
Unit of Measure
Items Envirco® MAC 10® LEDC 4 x 4 Fan Filter Units
1536
Envirco® MAC 10® LEDC 1950 Cubic Feet per Minute (ft³/min) Maximum Air Flowrate 4 x 4 Fan Filter Unit
Envirco® MAC 10® LEDC 4 x 4 Fan Filter Units
1537
Envirco® MAC 10® LEDC 1950 Cubic Feet per Minute (ft³/min) Maximum Air Flowrate 4 x 4 Fan Filter Unit
Envirco® MAC 10® LEDC 4 x 4 Fan Filter Units
1558
Envirco® MAC 10® LEDC 1950 Cubic Feet per Minute (ft³/min) Maximum Air Flowrate 4 x 4 Fan Filter Unit
Envirco® MAC 10® LEDC 4 x 4 Fan Filter Units
1559
Envirco® MAC 10® LEDC 1900 Cubic Feet per Minute (ft³/min) Maximum Air Flowrate Room Side Replacement 4 x 4 Fan Filter Unit
Envirco® MAC 10® LEDC 4 x 4 Fan Filter Units
1560
Envirco® MAC 10® LEDC 1900 Cubic Feet per Minute (ft³/min) Maximum Air Flowrate Room Side Replacement 4 x 4 Fan Filter Unit
Description N/A The MAC 10® LEDC 4 x 4 is a versatile fan filter unit that is designed for the most challenging cleanroom applications. It offers significant cost savings and electrical efficiencies for large cleanrooms.

The MAC 10® LEDC 4 x 4 maximizes energy efficiencies with its exclusive backward blower wheel design. It provides 90 fpm airflow up to 1.0" wg static pressure levels enabling cleanroom projects to operate cost effectively.
Brands N/A Envirco®
Nominal Unit Size N/A 4 x 4 ft
Active Filter Face Area N/A 14.4 ft² N/A 14.4 ft² N/A 14.4 ft² N/A 12.1 ft² N/A 12.1 ft²
Maximum Air Flowrate1 N/A 1950 ft³/min N/A 1950 ft³/min N/A 1950 ft³/min N/A 1900 ft³/min N/A 1900 ft³/min
Energy Consumption Rate at Maximum Air Flowrate N/A 580 W N/A 580 W N/A 580 W N/A 610 W N/A 610 W
Air Flowrate at 90 Feet per Minute (ft/min) Average Speed N/A 1300 ft³/min N/A 1300 ft³/min N/A 1300 ft³/min N/A 1100 ft³/min N/A 1100 ft³/min
Energy Consumption Rate at 90 Feet per Minute (ft/min) Average Speed N/A 220 W N/A 220 W N/A 220 W N/A 150 W N/A 150 W
Unit Weight N/A 135 lb N/A 135 lb N/A 135 lb N/A 150 lb N/A 150 lb
Dimension A N/A 47.63 in1210 mm
Dimension B N/A 47.63 in1210 mm
Dimension C N/A 16.67 in424 mm N/A 16.67 in424 mm N/A 16.67 in424 mm N/A 17.92 in455 mm N/A 17.92 in455 mm
Voltage N/A 115 V N/A 220 V N/A 277 V N/A 115 V N/A 220 V
Frequency N/A 50 Hz60 Hz N/A 50 Hz60 Hz N/A 60 Hz N/A 50 Hz60 Hz N/A 50 Hz60 Hz
Phase N/A 1
Full Load Current N/A 5.20 A N/A 3.20 A N/A 4.50 A N/A 5.20 A N/A 3.20 A
Filter Housing Material N/A Mill Finished Aluminum
Industry Standards / Certifications N/A cUL listed (115 V, 208-240 V, 277 V) with standard UL 900 filter, File number E152685 (UL507)
Filter Type N/A High Efficiency Particulate Air (HEPA)
Filtrand N/A Particulate
High Efficiency Particulate Air (HEPA) Filter Efficiency at 0.3 Micron Size N/A 99.9 %
External Static Operating Pressure N/A 1.0 inWg
Intended Application N/A Cleanrooms
Orientation N/A Horizontal
Environment N/A Chemical Resistant Corrosive Atmosphere
Construction N/A Welded aluminum cabinet with exterior finished in corrosion resistant polyurethane enamel.
  • Walkable Plenum 250 lb.
Filters N/A Aluminum framed High Efficiency Particulate Air (HEPA) type, with a minimum efficiency of 99.99 % at 0.3 micron, aerosol challenged (zero probed).
Airflow N/A 90 FPM ± 10 FPM average velocity, 6" from diffuser screen. Uniformity ± 20% of average or better.
Motor/Blower Assembly N/A Direct drive, continuous duty motor with sealed-for-life bearings and inherent overload protection. The blower assembly is electronically (dynamically) balanced and is designed to provide rated airflow through a 50 % increase in initial static pressure.
Additional Information N/A Fewer components mean lower installed costs. With use of the MAC 10® LEDC 4 x 4 unit, additional savings are captured in the ceiling plenum because less grid is required and fewer electrical connections are needed. Even better, this model also provides a lower sound level than most competitive 2 x 4 fan filter units.
Features N/A
  • Low sound, low watts, low profile, and low operating costs.
  • Energy efficient EC motor.
  • Universal control card offering local, Modbus, or analog options.
  • Aluminum construction with mill finish for durability.
  • Meets IEST recommended practices.
  • Protective inlet ring.
Optional Features N/A
  • Ultra Low Penetration Air (ULPA) filter - 99.9995 % efficient at 0.12 micron particle size.
  • DC Monitoring and Control System - Enables facility to adjust speed levels as required and assures that units are operating properly.
  • CE Marked - 230 V units available.
  • Exterior is available powder-coated or stainless steel for chemical resistance in corrosive environments.
  • Pressure switch with indicator light to show filter loading.
  • Green indicator light showing motor failure.
  • Room-side Replacement (RSR) available with gel seal filter element; filter is replaceable from the room-side.
  • RSRE provides filter and motor/blower assembly replacement from the room-side.
Note N/A Performance tested in accordance with the (ANSI/AMCA 210-07), (ANSI/ASHRAE 51-07) test standards for Certified Aerodynamic Performance Rating.

90 fpm values based on active filter face area.

BTU = Watts x 3.413.
  • 1 Maximum CFM rating base on free air volumes at high speed motor setting.