Print Back
The Hospi-Gard@ IsoClean® is a portable, self-contained high efficiency particulate air (HEPA) filtration system designed to easily and economically create a negative pressure isolation room that will meet OSHA and CDC TB guidelines.

The IsoClean® can be used as a positive pressure clean air recirculating system in clinics, waiting rooms, hospital emergency rooms and other confined areas or as a partial or complete exhausting system to create a negative pressure isolation room for possible use
more
Unit of Measure

Specifications

Dimension A

1740 mm

Dimension B

401 mm

Dimension C

604 mm

Dimension D

223 mm

cUL Listed

Yes

Airflow

High - 710 CFM Low - 430 CFM Medium - 530 CFM

Power Requirements

3.5 A at 230V/50 Hz

Shipping Weight

56.7 kg

Construction

Welded aluminum filter plenum and blower housing with a corrosion resistant polyurethane enamel finish. Four 2" (51 mm) casters, two locking

Filter

Aluminum Framed HEPA type, with a minimum efficiency of 99.99% at 0.3 micron, aerosol challenged. Airflow sensor indicates when the filter needs changing.

Prefilter

Disposable non-woven polyester media with frame - 30%

6 in. (152 mm) Exhaust Port

Located on top of the unit for use as a split system to create both negative pressure and clean air recirculation.

Motor/Blower Assembly

Direct drive, continuous duty, 1/3 Hp, 0.25 kW, 3-speed motor with sealed-for-life bearings and inherent overload protection located on the "clean side" of the filter. Motor/blower assembly is mounted on vibration dampening rubber mounts and designed to provide rated airflow through a 50% increase in initial static pressure.

Electrical

Standard 5-15P, 115 V, single phase, 60 Hz, rubber-covered cord with 3-prong hospital grade, grounded plug (Part No. 10850). Standard 6-15P, 220 V, single phase, 50/60 Hz, rubber- covered cord with 3-prong hospital grade, grounded plug (Part No. 10921).

Hospital Applications

N/A Aerosol Pentamidine Treatment Bronchoscopy Rooms Emergency Rooms Intensive Care Units Negative Pressure Rooms Renal Dialysis Rooms Sputum Induction Waiting Rooms

Other Applications

N/A Addiction Recovery Centers Clinics Correctional Facilities Homeless Shelters Nursing Centers Physician Offices

Options

N/A 8 in. (203 mm) 100% Exhaust Collar, Part No. 11055 Annunciator, Part No. 63338 Anti-Microbial Prefilter, Part No. 63352 Carbon Prefilter, Part No. 63349 IsoClean with ULPA Filter Upgrade, Part No. 10850-002 Keylock ON/OFF Switch, Part No. S11073-001 Minihelic Pressure Gauge, Part No. S11129-001 Room Pressure Monitor, Part No. 63337